DESCALING LIQUID

 RXSOL-11-1008-025


Scales are very damaging to the boiler because they interfere with the heat transfer and can lead to overheating and eventually, boiler rupture, To increase usable life of cleaned equipment , it is safe and effective way to remove scale deposits from all types of water-cooled and water-heated equipment This descaler specifica16, formulated Apo developed to rapidly clean mineral scale from passages in water.cooled or heated equipment.

It improves

  • Plant Efficiency
  • Lowers Cost
  • Conserves Energy
  • Decreases Down Time.

It does not contain toxic cresols or other tar oils that Require SARA Title III, Section 313 spill loss or disposal. Do not use concentrated 1008 on aluminium surfaces.

Benefits :

RXSOL-11-1008-025 Descaler has the ability to dissolve approximately 1.5kg of calcium carbonate scale per gallon in concentrated form. It does not need to be heated up during cleaning. The uniqueness of this Descaler allows you to clean some equipment while still in operation utilizing a minimum of your own personnel.

Active Matter: 68 72% Packaging: 25.00 Ur.

 

Why Use RXSOL Descaler?

You do not have to heat PXSOL 1008, RXSOL 1008 is safer for the employees to use than other acid products

Your equipment will be cleaned in only hours without disassembling any part of the equipment Equipment can also be cleaned without any down time (cleaning on the run)
Cleans down to the original surface without pitting
RXSOL 1008 is safe on copper, copper.nickel, bronze, brass, iron, stainless steel and rubber
RXSOL 1008 will extend the usable life of your equipment, especially when used as a part of a regularly scheduled preventative maintenance program
Removing the scale build up allows your equipment to operate more efficiently with less down time

Application: Boilers, Calorifiers, Heat exchanges, diesel engine cooling system. Condensers, Evaporators & other types of equipment where rust & scale form..

Dose:

RXSOL-11-1008-025 is mixed with fresh water 3 to 20 percent depending on deposition of scaling.
The most effective method is circulation for large systems or components like boilers, evaporators, condensers, heat exchangers and generally closed systems that have the capability to circulate at a temperature of approximately 40-60°C, for 6.12 hours and solutions of 10.40% of RXSOL-11-1008-025 in water Keep in mind that the strength of the solution is analogous to the degree of deposition of scale . In case of small components, the soak method in an immersion bath can be used. If the equipment to be cleaned is contaminated by oil, grease, sludge or carbonized oil, then first of all clean the system with degreaser PXSOL-10-1005.
RXSOL-11-1008-025 should be mixed with fresh water to form a solution of 5-30%, depending on the extent of scaling.
Precaution. It is essential to thoroughly rinse all metal surfaces at least once with a 0.5% solution of RX6020-2005 in fresh water This solution should be circulated for 2.4 hours or until an acceptable pH value is obtained. This will neutralize any remaining acidity & passivate steel surfaces.


Note:

After using PXSOL-11-1008-025, sense all metal surfaces with 0.5 percent of RXSOL-10.1005, at least 2.4 hour, up to neutral of PH value.
Fast and effective scale remover.
Soft on ferrous metals.
Removes water scale & rust from boilers/diesel engine E. other cooling system As well as from condensers, evaporators & heat exchangers etc



 

 